  Datasheet File OCR Text:
  d a t a sh eet supersedes data of september 2004 2008 sep 01 ferroxcube pts18/11 pt, pts, pts/i cores and accessories
2008 sep 01 1052 ferroxcube pt, pts, pts/i cores and accessories pts18/11 (1811ths) core sets effective core parameters symbol parameter value unit (i/a) core factor (c1) 0.770 mm ? 1 v e effective volume 1070 mm 3 i e effective length 28,7 mm a e effective area 37.2 mm 2 a min minimum area 31.0 mm 2 m mass of set 5.0 g handbook, halfpage 7.4 0.2 cbw112 10.6 0.15 10.5 min. 15.15 0.25 18.0 0.4 3.1 0.075 7.4 0.15 11.94 0.2 fig.1 pts18/11 core set. dimensions in mm. core sets for general purpose transformers and power applications clamping force for a l measurements, 20 5n. grade a l (nh) e air gap ( m) type number 3c81 100 3% 61 600 pts18/11-3c81-a100 160 3% 98 340 pts18/11-3c81-a160 250 3% 153 200 pts18/11-3c81-a250 315 3% 193 150 pts18/11-3c81-a315 400 5% 245 120 pts18/11-3c81-a400 3000 25% 1830 0 pts18/11-3c81 3c91 3000 25% 1830 0 pts18/11-3c91 3f3 100 3% 61 600 pts18/11-3f3-a100 160 3% 98 340 pts18/11-3f3-a160 250 3% 153 200 pts18/11-3f3-a250 315 3% 193 150 pts18/11-3f3-a315 400 5% 245 120 pts18/11-3f3-a400 2225 25% 1365 0 pts18/11-3f3
2008 sep 01 1053 ferroxcube pt, pts, pts/i cores and accessories pts18/11 (1811ths) core sets of high permeability grades clamping force for a l measurements, 15 5n. properties of core sets under power conditions note 1. measured at 60 c. bobbins and accessories coil formers, winding data and mounting parts are equal to those of ?p18/11? , but ?area product? is different. winding data and area product (for pts 18/11) for cp-p18/11 coil former winding data and area product (for pts18/11) for 6-pins p18/11 coil former for pcb mounting grade a l (nh) e air gap ( m) type number 3e27 5140 25% 3150 0 pts18/11-3e27 grade b (mt) at core loss (w) at h = 250 a/m; f = 25 khz; t=100 c f = 25 khz; = 200 mt; t = 100 c f = 100 khz; =100mt; t = 100 c f = 100 khz; = 200 mt; t = 100 c f=400khz; =50mt; t = 100 c 3c81 320 0.22 ?? ? 3c91 320 ? 0.055 (1) 0.4 (1) ? 3f3 315 ? 0.12 ? 0.2 number of sections winding area (mm 2 ) minimum winding width (mm) average length of turn (mm) area product ae x aw (mm 4 ) type number 1 17.1 5.7 36.6 636 cp-p18/11-1s 22 7.95 2 2.65 36.6 2 x 296 cp-p18/11-2s 33 4.95 3 1.6 36.6 3 x 184 cp-p18/11-3s number of sections minimum winding area (mm 2 ) nominal winding width (mm) average length of turn (mm) length of pins (mm) area product ae x aw (mm 4 ) type number 1 16.8 6.0 36.7 4.4 625 cpv-p18/11-1s-6pd 1 16.8 6.0 36.7 6.8 625 cpv-p18/11-1s-6pdl 22 7.61 2 2.8 36.7 4.4 2 x 283 cpv-p18/11-2s-6pd 22 7.61 2 2.8 36.7 6.8 2 x 283 cpv-p18/11-2s-6pdl 33 4.58 3 1.7 36.7 4.4 3 x 170 cpv-p18/11-3s-6pd 33 4.58 3 1.7 36.7 6.8 3 x 170 cpv-p18/11-3s-6pdl b ? b ? b ? b ?
2008 sep 01 1054 ferroxcube pt, pts, pts/i cores and accessories pts18/11 (1811ths) data sheet status definitions disclaimer life support applications ? these products are not designed for use in life support appliances, devices, or systems where malfunction of these products can reasonably be expected to result in personal injury. ferroxcube customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify ferroxcube for any damages resulting from such application. product status definitions data sheet status product status definitions preliminary specification development this data sheet contains prelimin ary data. ferroxcube reserves the right to make changes at any time without not ice in order to improve design and supply the best possible product. product specification production this data sheet contains final specifications. ferroxcube reserves the right to make changes at any time without notice in order to improve design and supply the best possible product. status indication definition prototype these are products that have been made as development samples for the purposes of technical evaluation only. the data for these types is provisional and is subject to change. design-in these products are recommended for new designs. preferred these products are recommended for use in current designs and are available via our sales channels. support these products are not recommended for new designs and may not be available through all of our sales channels. customers are advised to check for availability.


▲Up To Search▲   

 
Price & Availability of PTS18-3F3-A100

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X